HDV100A3 Command & Response Manual 7 Cover Page
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Setting Baud 1, Baud 2
Baud Rate Setup Table
Baud
Rate
Decimal
Divisor
Hex Divisor MSB
(Baud 2)
Hex Divisor LSB
(Baud 1)
9600
48
$00
$30
14400
32
$00
$20
19200
24
$00
$18
38,400
12
$00
$0C
57,600
8
$00
$08
115,200
4
$00 (default)
$04 (default)
230,400
2
$00
$02
460,800
1
$00
$01
All baud rates are entered as hex numbers. To calculate your own
decimal divisor use the following formula. The decimal number must be
converted to hexadecimal before entering the number. Baud rates below
9,600 are not recommended because of the difference in speed between the
vehicle bus and PC serial port.
The UART clock = 7,372,800 Hz
Decimal Divisor = Clock frequency ( 7,372,800)
Baud output x 16
If you want a baud rate of 9,600 baud
Decimal Divisor = 7,372,800
9,600 x 16
Decimal Divisor = 48 = 30 hex
Baud 1= 30
Baud 2= 00