Owners Manual
2800 Series Marquee
1.5 Single Drop, Full Duplex, RS-232 Wiring
After mounting the marquee, communications wiring will have to be installed. Inspect your unit for serial
communications connections. Some units, such as the black anodized aluminum versions come with a custom
pin-out DB25 connector. Other units such as the industrial steel versions provide RS-232, and RS-485 screw
terminals on a DIN rail barrier inside the enclosure requiring the customer to punch a conduit hole.
If only one marquee will be controlled from the PC or PLC, and the marquee is less than fifty cable feet away from
the PC/PLC, then single drop, full duplex, RS-232 communications wiring may be used. RS-232 is typically more
convenient than RS-485 communications, but RS-232 can only be used over short distances. A full duplex
communications link allows the marquee to send information back to the controlling PC/PLC.
Page 4 PB-2149-335B
2800 FACTORY WIRING
RS-232 OUT
RS-232 IN
RS-485 -
RS-485 +
SIGNAL GND
120VAC NEUT
120VAC HOT
EARTH GND
LB-2815-006
(2) RXD
(3) TXD
(5) GND
Standard PC DB9
Connector Illustrated
Standard PC DB9
Connector Illustrated
(2) RXD
(3) TXD
(5) GND
(15) RS-232 OUT
(14) RS-232 IN
(21) GROUND
2800 DB25 CONNECTOR