Dip Switch Settings
There are 6 operation modes defined by the 3 switches. They are defined in the
following table.
Sw1 Sw2 Sw3 Mode
On On On Console
Off On On Upgrade
On Off On Default
Off On Off RS-232
On Off Off RS-422
Off Off Off RS-485
Console Mode
The console mode allows access to the ESP901 setup menu. This is one way to
reconfigure the default settings for the application. A serial connection is made
between a COM port on the PC and the serial port of the ESP901 with a null modem
cable. In console mode, the serial port defaults to an RS-232 interface.
The ESP901 serial port default settings are, baud rate 9600, 8 data bits, no parity, and
1 stop bit. Hyper Terminal should be used for this type of setup. Hyper Terminal’s
serial settings are configured the same as the mentioned default settings of the ESP901
and must be set to VT100 emulation mode. The default settings are used only if they
have not been changed.
See Chapter 7 for details.
Upgrade
The newest firmware can be installed on the ESP901 using the PC’s serial port or the
Virtual COM port. Some firmware upgrades may require a new software upgrade with
the Virtual COM driver being the critical component.
See Chapter 11 for details.
Default Setting
When the switches are set to this mode the ESP901 will reset to the original default
settings.