Advanced Programming
AT Commands
Example: Using Hyper Terminal Software to change the module's DT (Destination
Address) parameter and save the new address to non-volatile memory. A serial
connection to a PC is required.
Method 1 (One line per command)
OK <CR> (Enter into Command Mode)_
{current value} <CR> (Read Destination Address)_
OK <CR> (Modify Destination Address)_
OK <CR> (Write to non-volatile memory)_
OK <CR> (Exit Command Mode)
Method 2 (Multiple commands on one line)
OK <CR> (Enter into Command Mode)
{current value} <CR> (Read Destination Address)
OK <CR> (Execute commands)
Note: When using hyper terminal to program a modem, PC com port settings must match the baud
(interface data rate), parity & stop bits parameter settings of the module.
Note: Do not send commands to the module during flash programming (when parameters are
being written to the module registry).
Wait for the OK sys tem response that follows the ATWR command before entering the next
command or use flow control.